Reflexofeu - Simple & Effective Fire Detection and Suppression

Electrical enclosure criticality study

Not all your electrical enclosures carry the same weight for your site. These online studies rank them for you, from what your teams can observe: no measuring instrument is needed and no prior intervention either. At the end, you know which ones to deal with first and which ones to protect against fire, with the reasoning behind every decision.

Two routes are offered, depending on the time you have. They complement each other: the quick walkthrough sorts, the full study analyses. Both are free and need no sign-up.

10 minutes · 15 to 30 enclosures

Quick walkthrough

A first pass, enclosure by enclosure, to find out which ones deserve a closer look. Four questions each, no rating to do.

  • Area, impact of a failure, visual observation
  • Dimensions and photos if you want them
  • Three piles out: study as a priority, to be studied, no warning sign
Run the quick walkthrough

Ideal for a first stocktake, or for a set of enclosures you do not know yet.

15 to 20 minutes · about ten enclosures

Full FMECA study

The criticality analysis proper, following the FMECA method. It produces the risk priority number, the A/B/C classification and the fire-protection recommendations.

  • Seven operating factors per enclosure
  • Failures rated on severity, occurrence and detectability
  • Decisions D1 to D4 and a full, reasoned report
Start the full study

The one to pick if you are after an action plan, an insurance file or a budget.

The two follow on from each other

At the end of the quick walkthrough, a button carries the flagged enclosures into the full study: their name, their area, their dimensions, your photos and the impact of a failure are already in place. You re-enter nothing, you complete.

What you get

Here is an extract from the report produced at the end of the study, on a fictitious site of thirteen enclosures. The full report downloads as a single file, readable by your management and by your insurer alike.

CRITICALITY REPORT — ELECTRICAL ENCLOSURES

ReflexOFeu · FMECA to IEC 60812 · observable criteria & operating factors

3
Immediate corrective action
7
Scheduled within 1 month
11
Enhanced preventive maintenance
14
Acceptable
AreaCriticalityEnclosuresClass ATo protectMax RPN
Utilities (air, cooling, steam)4/4432288
Production — main line4/4522216
Packaging3/420090
Logistics / dispatch2/420048
P1Workshop main switchboard288

Class A · high fire risk · protect as a priority

Failures that could start a fire: loose connections (RPN 288), fouling (RPN 90). Aggravating factors: ageing enclosure, load near maximum.

P1Air compressor enclosure216

Class A · high fire risk · protect as a priority

Failures that could start a fire: visible overheating (RPN 216), ventilation failure (RPN 120). Aggravating factors: harsh environment.

P2Line 2 enclosure135

Class B · moderate fire risk · to be protected

Failures that could start a fire: contact oxidation (RPN 135). Aggravating factors: harsh environment.

FactorLevelRatingWeightPts
Plant areaUtilities — major shutdown / safety4/4×14
Production impactThe whole site4/4×14
RedundancyNone4/4×14
Age15–25 years3/4×13
Load70–90 %3/4×13
Safety systems suppliedFire detection3/4×13

Extract from a fictitious report, for illustration.

FMECA method — IEC 60812

The study applies failure mode, effects and criticality analysis as defined by IEC 60812. For each failure considered on an enclosure, three criteria are rated from 1 to 10, independently of one another. Their product gives the risk priority number (RPN), from 1 to 1000.

Severity (S)

What happens if the failure occurs: from a minor nuisance to fire ignition, by way of a line stoppage and a site shutdown.

Occurrence (O)

How often it is liable to occur: from never observed to constant, in the light of the enclosure's age, environment and history.

Detectability (D)

How far it would go unnoticed: from an alarm that flags it to a fault undetectable without dismantling. The fainter the signs, the higher the rating.

The RPN alone is not enough: a high-RPN failure on a secondary enclosure does not carry the same weight as the same failure on the main switchboard. The study therefore combines the RPN with the enclosure's class, which adds up the criticality of its area and seven operating factors.

The decision scale

Every rated failure receives a decision, based on its RPN and the enclosure's class. The thresholds are adjustable in the tool: those shown here are the defaults.

D1
Immediate corrective action
RPN ≥ 200, or class A and RPN ≥ 100
D2
Scheduled within a month
RPN ≥ 100
D3
Enhanced preventive maintenance
RPN ≥ 40
D4
Acceptable
Below 40

Should this enclosure be protected?

The study answers that question enclosure by enclosure. The fire risk level is established from the failures liable to set the enclosure alight alone — connection overheating, corrosion, fouling, insulation faults, ventilation, pest intrusion — and from the aggravating factors noted: age, load, environment.

P1
Protect as a priority
High fire risk on a class A enclosure
P2
To be protected
High risk, or moderate risk on a class A or B enclosure
P3
To be reassessed
Moderate risk, decision to revisit after corrective action
—
No protection needed as things stand
No flammable failure identified

Quick walkthrough or full study?

Both rest on the same field observations and need no measuring instrument. What separates them is the depth of analysis — and therefore what you can do with the result.

Quick walkthroughFull FMECA study
Duration10 minutes for 15 to 30 enclosures15 to 20 minutes for about ten enclosures
Questions per enclosure47 factors, plus the rating of each failure
Rating to doNoneSeverity, occurrence, detectability out of 10
MethodTriage on stakes and visual observationFMECA — IEC 60812
ResultThree piles: study as a priority, to be studied, no warning signRPN, A/B/C class, decisions D1 to D4, reading by area
Fire protectionNot coveredPriorities P1, P2, P3 with reasoning
Adjustable scaleNo — fixed scaleYes — weightings, thresholds and areas
ReportSorted list, downloadableFull reasoned report, photos included
Who forA first stocktake, a poorly known set of enclosuresAn action plan, an insurance file, a budget

If you are unsure, start with the quick walkthrough: it will tell you on how many enclosures the full study is worth running, and you will find them already entered when you come to run it. Quick walkthrough

How the full study runs

1

You set the scale

You pick your industry to load a pre-rated breakdown of areas, which you then adjust. The defaults suit most sites.

2

You describe your enclosures

Name, area, dimensions, then seven simple questions on their role and condition. You can attach photos, taken straight from your phone.

3

You list the possible failures

For each enclosure, you pick the plausible failures from a library of twelve, then you rate them on three criteria.

4

You get the report

Action priorities, enclosures to protect, a reading by area and the full reasoning behind each decision.

Allow about fifteen minutes for ten enclosures. The study can be run on a phone, standing in front of the enclosures, or at a desk from your own records. If you arrive from a quick walkthrough, the first two steps are already done.

Industries covered

Twelve sector breakdowns are offered, each with its areas already rated. They are starting points built by trade, to be adjusted against your own site.

Generic industrial site
Food and beverage
Plastics and injection moulding
Metalworking and machining
Chemicals and cosmetics
Pharmaceuticals
Wood and industrial joinery
Printing and paper-board
Logistics and warehousing
Surface treatment
District heating plant and heat network
Recycling and waste sorting centre

Frequently asked questions

Is the criticality study free?

Yes, both of them. The tools are freely accessible and the reports download at no cost and with no commitment.

What is the difference between the quick walkthrough and the full study?

The quick walkthrough asks four questions per enclosure and sorts them into three piles: study as a priority, to be studied, no warning sign. It computes neither a risk priority number nor an A/B/C class, and does not cover fire protection. The full study applies the FMECA method to seven operating factors and to each rated failure: it produces the RPN, the classification, decisions D1 to D4 and the protection recommendations.

Which one should I start with?

The quick walkthrough if you have many enclosures, or if you do not yet know which ones are a problem: ten minutes are enough to sort them. Straight to the full study if you have already identified about ten sensitive enclosures and need a costable action plan.

Do I have to re-enter everything to move from the walkthrough to the full study?

No. At the end of the walkthrough, a button carries the flagged enclosures into the full study, with their name, their area, their dimensions, their photos and the impact of a failure. The six other operating factors remain to be filled in, along with the rating of the failures observed. Until that is done, the report states clearly that the classification is provisional.

Is a measuring instrument or a site visit required?

No. Every rating rests on visual observations and operating data your teams already know: heat marks, corrosion, fouling, failure history, equipment age. No thermal camera and no prior inspection are needed.

Which standard is the method based on?

On IEC 60812, which defines failure mode, effects and criticality analysis. The rating scales have been adapted to the particular case of industrial electrical enclosures, and the rule that the three criteria must be rated independently is respected.

Can I adapt the thresholds and the areas to my site?

Yes, and it is recommended. You weight each factor, you set your own class and decision thresholds, and you define your areas with their criticality. The report records the parameters applied, which makes the classification verifiable by a third party.

What does the report contain?

The summary of decisions, the reading by area, the fire-protection recommendations ranked by priority, then for each enclosure the detail of its classification and of every rated failure, with the reasoning behind the decision. Attached photos appear in it, and the study's parameters are restated at the end of the document.

Is my data kept?

Your details are stored so that the study can be sent to you and, where relevant, so that we can support you on the critical enclosures identified. They are kept for three years. You can request access to them or their deletion at any time.

Going further

The ratings rest on your statements and on visual observations. The study replaces neither the statutory inspection of your electrical installations nor an on-site survey. It is a prioritisation tool, to be reviewed once a year.

Start the full study

Free, no sign-up — the tool opens in your browser.

Or run the quick walkthrough first

Ten minutes to sort your enclosures, then automatic carry-over into the full study.

A question, a project?

Contact our team to study the fire protection of your electrical cabinets.

Contact us